BASLER ace acA4112-8gc

basler 5The Basler acA4112-8gc GigE camera with the Sony IMX304 CMOS sensor delivers 8 frames per second at 12.3 MP Resolution.

SKU: acA4112-8gc Category: Tags: , ,

Description

Sensor Vendor Sony
SensorIMX304
ShutterGlobal Shutter
Max. Image Circle1.1″
Sensor TypeCMOS
Sensor Size14.1mm x 10.3mm
Resolution (H x V)4096px x 3000px
Resolution12MP
Pixel Size (H x V)3.45 µm x 3.45 µm
Frame Rate8 fps
Mono/ColorColor
InterfaceGigE
Video Output Format
  • Mono 8
  • Bayer RG 8
  • Bayer RG 12p (Bayer RG 12 Packed)
  • Bayer RG 12
  • YUV 4:2:2 (YUYV) Packed
  • YUV 4:2:2 Packed
Pixel Bit Depth 10 or 12 bits
Synchronization
  • Software Trigger
  • Free-run
  • Hardware Trigger
Exposure Control
  • Hardware Trigger
  • Programmable via the camera API
Digital Input1
Digital Output1
General Purpose I/O1
Power Requirements
  • PoE or 12-24 VDC
Power Consumption (typical)2.8W
Power Consumption (PoE)3.3W
Housing TypeBox
Housing Size (L x W x H)50mm x 40mm x 30mm
Lens MountC-mount
Housing Temperature0 – 50°C
Weight (typical)90g
Conformity 
  • CE
  • RoHS
  • GenICam
  • GigE Vision
  • IP30
  • FCC
  • UL (in preparation)
Chunks
  • CRC Checksum
  • Exposure Time
  • Frame Counter
  • Gain Raw
  • Line Status All
  • Sequence Set Index
  • Timestamp
  • Trigger Input Counter
Color Creation and Enhancement
  • Balance White (Manual White Balance)
  • Balance White Auto (Automatic White Balance)
  • Color Adjustment (6-axis Hue/Saturation)
  • Color Transformation (RGB to RGB)
  • Light Source Presets
  • sRGB Gamma Correction
Event Reporting 
  • Acquisition Start
  • Acquisition Start Overtrigger
  • Acquisition Start Wait
  • Critical Temperature
  • Exposure End
  • Frame Start
  • Frame Start Overtrigger
  • Over Temperature
GigE Vision 2.0
  • Action Commands (Synchronous Triggering)
  • Precision Time Protocol (IEEE 1588)
  • Scheduled Action Commands
Image Acquisition Control
  • Acquisition Start Trigger
  • Acquisition Status
  • Frame Start Trigger
  • Trigger Delay
  • Triggered by Hardware
  • Triggered by Software
Miscellaneous
  • Device Information Parameters
  • Device Temperature
  • Remove Parameter Limits
  • User Defined Values
  • User Sets (Configuration Sets)
PGI
  • 5 x 5 Debayering
  • Color-Anti-Aliasing
  • Denoising
  • Improved Sharpness
Physical Interface and I/O Control
  • Line Source Signals: Acquisition Start Wait
  • Line Source Signals: Exposure Active
  • Line Source Signals: Frame Start Wait
  • Line Source Signals: Sync User Output
  • Line Source Signals: Timer Active
  • Line Source Signals: User Output
Pixel Formats
  • Bayer 12
  • Bayer 12p (Bayer 12 Packed)
  • Bayer 8
  • Mono 8
  • YCbCr422_8 (YUV422_8)
Standard Features 
  • Auto Function Profile
  • Black Level
  • Digital Shift
  • Exposure Auto
  • Exposure Mode: Trigger Width (Control via External Trigger)
  • Gain
  • Gain Auto
  • Gamma Correction
  • Lookup Table (LUT)
  • Region of Interest (ROI)
  • Reverse X (Horizontal Mirroring)
  • Reverse Y (Vertical Mirroring)
  • Sequencer
  • Test Images